- All Products
- Industrial Automation and Controls
- Monitor - Relay Output
| Image | Part # | Manufacturer | Description | Availability | Pricing | Quantity | Factory Lead Time | Mounting Type | Surface Mount | Transistor Element Material | Approvals | Manual Reset | Manufacturer | Manufacturer Part Number | Mounting | Number of Elements | Operating Temperature | Published | Series | JESD-609 Code | Part Status | Moisture Sensitivity Level (MSL) | Number of Terminations | ECCN Code | Type | Terminal Finish | Additional Feature | Voltage - Supply | Terminal Position | Terminal Form | Peak Reflow Temperature (Cel) | Time@Peak Reflow Temperature-Max (s) | JESD-30 Code | Qualification Status | Output Type | Circuit | Configuration | Case Connection | Transistor Application | Number of Phases | Contact Rating @ Voltage | Power Dissipation-Max (Abs) | Turn On Time | Collector Current-Max (IC) | Turn Off Time-Nom (toff) | Delay Time | Collector-Emitter Voltage-Max | Gate-Emitter Voltage-Max | Gate-Emitter Thr Voltage-Max | Trip Range | Trip Status | RoHS Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr. Part #250ATwicea Part #461-457-250A | Littelfuse Inc. |
3-PHASE VOLTAGE MONITOR/ 190-4
Datasheet
Compare
| 2125
In Stock
| Min.:1 Mult.:1 | 6 Weeks | Chassis Mount | NO | SILICON | - | - | - | - | - | 1 | -40°C~70°C | - | 250A | e1 | Active | Not Applicable | 3 | - | Voltage Sensing AC | Tin/Silver/Copper (Sn/Ag/Cu) | UL RECOGNIZED, HIGH RELIABILITY | 190V~480VAC | SINGLE | THROUGH-HOLE | NOT SPECIFIED | NOT SPECIFIED | R-PSIP-T3 | Not Qualified | Relay | DPDT (2 Form C) | SINGLE | ISOLATED | POWER CONTROL | - | 10A @ 240VAC | 250W | 150 ns | 19A | 850 ns | Fixed, 4 Sec | 2500V | 20V | 8V | 190 ~ 480V AC | Energized High/Low | ROHS3 Compliant | |
| 250A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #SCR430TTwicea Part #461-457-SCR430T | Littelfuse Inc. |
GLOVE, POLYAMIDE, L/FREE, PU, SIZE 6 - More Details
Datasheet
Compare
| 2709
In Stock
| Min.:1 Mult.:1 | 6 Weeks | - | - | - | - | - | - | - | - | - | - | 2016 | SCR | - | Active | Not Applicable | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ROHS3 Compliant | |
| SCR430T | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #201ATwicea Part #461-457-201A | Littelfuse Inc. |
3-PHASE PLUG-IN VOLTAGE MONITO
Datasheet
Compare
| 2403
In Stock
| Min.:1 Mult.:1 | 6 Weeks | Socketable | YES | SILICON | - | - | - | - | - | 1 | -20°C~70°C | - | 201A | - | Active | Not Applicable | 2 | EAR99 | Voltage Asymmetry, Voltage Sensing AC | - | - | 190V~480VAC | SINGLE | GULL WING | NOT SPECIFIED | NOT SPECIFIED | R-PSSO-G2 | Not Qualified | Relay | SPDT (1 Form C) | SINGLE WITH BUILT-IN DIODE AND RESISTOR | COLLECTOR | POWER CONTROL | - | 10A @ 240VAC | - | 6500 ns | 20A | 18500 ns | Fixed, 2 Sec, 4 Sec | 400V | - | - | 190 ~ 480V AC | Energized Low | ROHS3 Compliant | |
| 201A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #111P-ENCLTwicea Part #461-457-111P-ENCL | Littelfuse Inc. |
1-PHASE PUMPSAVERPLUS / 115 V
Datasheet
Compare
| 2181
In Stock
| Min.:1 Mult.:1 | 6 Weeks | Chassis Mount | - | - | - | - | - | - | - | - | -40°C~55°C | 2015 | 111P | - | Active | Not Applicable | - | - | Voltage Sensing AC | - | - | 115VAC | - | - | - | - | - | - | Relay | SPST-NO (1 Form A) | - | - | - | - | 16A @ 120VAC | - | - | - | - | Fixed, 4 Sec, 5 Sec | - | - | - | 95 ~ 132.5V AC | Energized High/Low | ROHS3 Compliant | |
| 111P-ENCL | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #TVM480A101S2STwicea Part #461-457-TVM480A101S2S | Littelfuse |
SSAC Protection Relays, TVM Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UR | - | SSAC | TVM480A101S2S-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| TVM480A101S2S | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSW4HBCTTwicea Part #461-457-ECSW4HBCT | Littelfuse |
SSAC Protection Relays, ECSW Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSW4HBCT-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSW4HBCT | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PLM9804Twicea Part #461-457-PLM9804 | Littelfuse |
SSAC Protection Relays, PLM Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | No | SSAC | PLM9804-SSAC | Plug-In | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| PLM9804 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #TVM208A101S1STwicea Part #461-457-TVM208A101S1S | Littelfuse |
SSAC Protection Relays, TVM Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UR | - | SSAC | TVM208A101S1S-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| TVM208A101S1S | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSL30BDTwicea Part #461-457-ECSL30BD | Littelfuse |
SSAC Protection Relays, ECSL Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSL30BD-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSL30BD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PLM9806Twicea Part #461-457-PLM9806 | Littelfuse |
SSAC Protection Relays, PLM Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | No | SSAC | PLM9806-SSAC | Plug-In | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| PLM9806 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECS3HBTwicea Part #461-457-ECS3HB | Littelfuse |
SSAC Protection Relays, ECS Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECS3HB-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECS3HB | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSH31BTwicea Part #461-457-ECSH31B | Littelfuse |
SSAC Protection Relays, ECSH Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSH31B-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSH31B | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSH31BDTwicea Part #461-457-ECSH31BD | Littelfuse |
SSAC Protection Relays, ECSH Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSH31BD-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSH31BD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSW4LBDTTwicea Part #461-457-ECSW4LBDT | Littelfuse |
SSAC Protection Relays, ECSW Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSW4LBDT-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSW4LBDT | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PLM6506Twicea Part #461-457-PLM6506 | Littelfuse |
SSAC Protection Relays, PLM Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | No | SSAC | PLM6506-SSAC | Plug-In | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| PLM6506 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #50R-115Twicea Part #461-457-50R-115 | Littelfuse |
Symcom Protection Relays, 50R Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | - | - | Symcom | 50R115 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 50R-115 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #777-KW/HPTwicea Part #461-457-777-KW/HP | Littelfuse |
Symcom Protection Relays, 777 Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | UL | Yes | Symcom | 777-KW/HP-P2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 777-KW/HP | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #777-MVTwicea Part #461-457-777-MV | Littelfuse |
Symcom Protection Relays, 777 Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | - | Yes | Symcom | 777-MV | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 777-MV | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSH41ATwicea Part #461-457-ECSH41A | Littelfuse |
SSAC Protection Relays, ECSH Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSH41A-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSH41A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #ECSH4HBGTwicea Part #461-457-ECSH4HBG | Littelfuse |
SSAC Protection Relays, ECSH Series
Datasheet
Compare
| Min.:1 Mult.:1 | - | - | - | - | CE, CSA, UL | - | SSAC | ECSH4HBG-SSAC | Surface | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ECSH4HBG |
Index :
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ





