- All Products
- Circuit Protection
- Circuit Breakers
| Image | Part # | Manufacturer | Description | Availability | Pricing | Quantity | Factory Lead Time | Mounting Type | Base Product Number | Brand | Factory Pack QuantityFactory Pack Quantity | Ihs Manufacturer | Illuminated | Lead Free Status / RoHS Status | Manufacturer | Manufacturer Part Number | Maximum Operating Temperature | Mfr | Minimum Operating Temperature | Mounting Styles | Package | Part # Aliases | Part Life Cycle Code | Product Status | Risk Rank | RoHS | Rohs Code | Unit Weight | Voltage Rating AC | Voltage Rating DC | Voltage, Rating | Series | Part Status | Moisture Sensitivity Level (MSL) | Type | Subcategory | Current Rating (Amps) | Reach Compliance Code | Current Rating | Termination Style | Approval Agency | Actuator Type | Illumination Voltage (Nominal) | Number of Poles | Illumination | Breaker Type | Circuit Protection Type | Product | Compliance | Product Category | Height | Length | Width |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr. Part #LELBX1-1-63-20.0-AFX-M3-VTwicea Part #734-149-LELBX1-1-63-20.0-AFX-M3-V | Sensata-Airpax |
CIR BRKR MAG-HYDR
Datasheet
Compare
| Min.:1 Mult.:1 | - | Panel Mount | LELBX1 | - | - | - | - | -- | - | - | - | Sensata-Airpax | - | - | Bulk | - | - | Active | - | - | - | - | 415 V | 80 V | - | LEL | Active | -- | - | - | 20A | - | - | - | - | Rocker | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | ||
| LELBX1-1-63-20.0-AFX-M3-V | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #IEL1-1REC4-59-4.00-01-VTwicea Part #734-149-IEL1-1REC4-59-4.00-01-V | Sensata-Airpax |
CIR BRKR MAG-HYDR
Datasheet
Compare
| 26
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | IEL1 | - | - | - | - | -- | - | - | - | Sensata-Airpax | - | - | Bulk | - | - | Active | - | - | - | - | 250 V | 80 V | - | IEL | Active | -- | - | - | 4A | - | - | - | - | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | |
| IEL1-1REC4-59-4.00-01-V | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #LELBX1-1-62-15.0-AF-M3-VTwicea Part #734-149-LELBX1-1-62-15.0-AF-M3-V | Sensata-Airpax |
CIR BRKR MAG-HYDR
Datasheet
Compare
| Min.:1 Mult.:1 | - | Panel Mount | LELBX1 | - | - | - | - | -- | - | - | - | Sensata-Airpax | - | - | Bulk | - | - | Active | - | - | - | - | 415 V | 80 V | - | LEL | Active | -- | - | - | 10A | - | - | - | - | Rocker | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | ||
| LELBX1-1-62-15.0-AF-M3-V | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #EA1-B0-14-810-2DA-BBTwicea Part #152-149-EA1-B0-14-810-2DA-BB | Carling Technologies |
Magnetic Circuit Breaker,
Datasheet
Compare
| 48
In Stock
| Min.:1 Mult.:1 | 4 Weeks | Panel Mount | - | - | - | CARLING TECHNOLOGIES INC | - | - | Carling Technologies | EA1-B0-14-810-2DA-BB | + 85 C | Carling Technologies | - 40 C | - | Bulk | - | Active | Active | 5.55 | - | Yes | - | 600 V | 125 V | - | E | - | - | Supplementary Protector / Motor Controller | - | 100A | compliant | - | - | CCC, CSA, UL508, UL1077 | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | Circuit Breakers | - | - | - | - | - | |
| EA1-B0-14-810-2DA-BB | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #CA2-B0-24-610-121-CGTwicea Part #152-149-CA2-B0-24-610-121-CG | Carling Technologies |
Magnetic Circuit Breaker,
Datasheet
Compare
| 2282
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | Not Illuminated | - | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | - | Active | - | Details | - | 8 oz | 240 V | 80 VDC | - | C | - | - | Hydraulic-Magnetic | Circuit Breakers | 10A | - | 10 A | Screw | CSA, UL489 | Handle | - | 2 Pole | None | Magnetic (Hydraulic Delay) | - | Circuit Breakers | - | Circuit Breakers | - | 63.2 mm | 1.95 mm | |
| CA2-B0-24-610-121-CG | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #MD2-B-34-490-1-A46-2-CTwicea Part #152-149-MD2-B-34-490-1-A46-2-C | Carling Technologies |
Magnetic Circuit Breaker,
Datasheet
Compare
| 18
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | - | Carling Technologies | MD2-B-34-490-1-A46-2-C | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | Active | Active | 5.55 | Details | - | 2.116438 oz | 250 V | 80 VDC | - | M | - | - | Supplementary Protector | Circuit Breakers | 9A | compliant | 9 A | Quick Connect | CSA, UL1077 | Rocker | - | 2 Pole | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | Circuit Breakers | - | Circuit Breakers | 39.62 mm | 48.26 mm | 35.41 mm | |
| MD2-B-34-490-1-A46-2-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #MS1-B-14-625-1-1BD-A-CTwicea Part #152-149-MS1-B-14-625-1-1BD-A-C | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 2946
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | - | - | 1.763698 oz | 240 V | 65 V | - | M | - | - | - | Circuit Breakers | 25A | - | - | - | cURus, UL | Toggle | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | - | - | |
| MS1-B-14-625-1-1BD-A-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #AB2-B0-34-625-3D1-CTwicea Part #152-149-AB2-B0-34-625-3D1-C | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 12
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | Details | - | - | 277 V | 80 V | - | A | - | - | - | Circuit Breakers | 25A | - | - | - | CSA, UL | Lever | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | - | - | |
| AB2-B0-34-625-3D1-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #AA1-B0-12-620-5D1-CTwicea Part #152-149-AA1-B0-12-620-5D1-C | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 12
In Stock
| Min.:1 Mult.:1 | 4 Weeks | Panel Mount | - | - | - | CARLING TECHNOLOGIES INC | Not Illuminated | - | Carling Technologies | AA1-B0-12-620-5D1-C | + 85 C | Carling Technologies | - 40 C | - | Bulk | - | Active | Active | 5.57 | - | Yes | - | 277 V | 80 V | - | A | - | - | Hydraulic-Magnetic | - | 20A | compliant | 20 A | - | CSA, UL | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | Circuit Breakers | - | - | - | - | - | |
| AA1-B0-12-620-5D1-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #AC1-B0-24-480-134-DTwicea Part #152-149-AC1-B0-24-480-134-D | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| Min.:1 Mult.:1 | 4 Weeks | Panel Mount | - | - | - | CARLING TECHNOLOGIES INC | - | - | Carling Technologies | AC1-B0-24-480-134-D | - | Carling Technologies | - | - | Bulk | - | Active | Active | 5.57 | - | Yes | - | 277 V | 80 V | - | A | - | - | - | - | 8A | compliant | - | - | CSA, VDE, UL | Rocker | - | 1 | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | ||
| AC1-B0-24-480-134-D | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #CX2-B0-14-470-31A-13STwicea Part #152-149-CX2-B0-14-470-31A-13S | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 2604
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | - | - | - | - | 500 V | - | CX | - | - | - | Circuit Breakers | 7A | - | - | - | TUV, UL489 | Lever | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | - | - | |
| CX2-B0-14-470-31A-13S | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #CA1-B2-14-615-A21-MFTwicea Part #152-149-CA1-B2-14-615-A21-MF | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 12
In Stock
| Min.:1 Mult.:1 | 4 Weeks | Panel Mount | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | - | Carling Technologies | CA1-B2-14-615-A21-MF | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | Active | Active | 5.57 | - | - | 4 oz | 480 V | 80 V | 240 VAC, 80 VDC | C | - | - | Hydraulic-Magnetic | Circuit Breakers | 15A | compliant | 15 A | Stud | CSA, VDE, UL489 | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | Circuit Breakers | UL489 Listed; CSA; VDE | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm | |
| CA1-B2-14-615-A21-MF | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #MS1-M-14-612-E-1CB-A-0AATwicea Part #152-149-MS1-M-14-612-E-1CB-A-0AA | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 2900
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | - | - | - | 240 V | 65 V | - | M | - | - | - | Circuit Breakers | 12A | - | - | - | - | Toggle | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | - | - | |
| MS1-M-14-612-E-1CB-A-0AA | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #CA2-B2-44-610-622-ETwicea Part #152-149-CA2-B2-44-610-622-E | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 2268
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | Not Illuminated | - | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | - | Active | - | - | - | 8 oz | 480 V | 150 V | 240 VAC, 125 VDC | C | - | - | Hydraulic-Magnetic | Circuit Breakers | 10A | - | 10 A | Stud | CSA, TUV, UL | Lever | - | 2 | None | Magnetic (Hydraulic Delay) | - | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 38.48 mm | |
| CA2-B2-44-610-622-E | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #MT1-B-14-610-3-A21-B-ETwicea Part #152-149-MT1-B-14-610-3-A21-B-E | Carling Technologies |
CIRCUIT BREAKER
Datasheet
Compare
| 22
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | - | - | 1.058219 oz | 250 V | 80 V | - | M | - | - | - | Circuit Breakers | 10A | - | - | - | CSA, TUV, UL | Push-Pull | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | - | - | |
| MT1-B-14-610-3-A21-B-E | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #AF1-B0-46-495-131-CTwicea Part #152-149-AF1-B0-46-495-131-C | Carling Technologies |
Magnetic Circuit Breaker,
Datasheet
Compare
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | Details | - | 2.292808 oz | 277 V | 80 VDC | - | A | - | - | Supplementary Protector / Motor Controller | Circuit Breakers | 9.5A | - | - | - | CSA, UL | Rocker | - | 1 | None | Magnetic (Hydraulic Delay) | - | Circuit Breakers | - | Circuit Breakers | - | - | - | ||
| AF1-B0-46-495-131-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #MF2-B-92-450-3-JC2-2-CTwicea Part #152-149-MF2-B-92-450-3-JC2-2-C | Carling Technologies |
-
Datasheet
Compare
| 2038
In Stock
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | Illuminated | - | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | - | Active | - | Details | - | 2.116438 oz | 250 V | 80 VDC | - | M | - | - | Supplementary Protector | Circuit Breakers | 5A | - | 5 A | Screw | CSA, UL1077 | Rocker | 9 ~ 16V | 2 Pole | Green | Magnetic (Hydraulic Delay) | - | Circuit Breakers | - | Circuit Breakers | 39.62 mm | 49.28 mm | 35.41 mm | |
| MF2-B-92-450-3-JC2-2-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #4420.0940Twicea Part #685-149-4420.0940 | Schurter |
Thermal Magnetic Circuit Breaker,
Datasheet
Compare
| Min.:1 Mult.:1 | 4 Weeks | - | - | Schurter | 3 | SCHURTER AG | - | - | Schurter | 4420.0940 | - | - | - | - | - | 4420.094 | Obsolete | - | 5.84 | - | Yes | 13.756845 oz | - | - | - | AS168X | - | - | - | Circuit Breakers | - | compliant | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | Circuit Breakers | - | - | - | ||
| 4420.0940 | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #CA2-B0-24-615-311-CTwicea Part #152-149-CA2-B0-24-615-311-C | Carling Technologies |
Circuit Breakers 2 POLE W/OUT AUX SWITCH
Datasheet
Compare
| 2743
In Stock
| Min.:1 Mult.:1 | 4 Weeks | Panel Mount | - | Carling Technologies | 10 | CARLING TECHNOLOGIES INC | Not Illuminated | - | Carling Technologies | CA2-B0-24-615-311-C | + 85 C | Carling Technologies | - 40 C | Panel Mount | Bulk | - | Active | Active | 5.11 | Details | - | 8 oz | 480 V | 80 VDC | 480 VAC, 80 VDC | C | - | - | Hydraulic-Magnetic | Circuit Breakers | 15A | compliant | 15 A | Screw | CSA, UL | Handle | - | 2 Pole | None | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 38.48 mm | |
| CA2-B0-24-615-311-C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #AC2-B0-26-620-131-CTwicea Part #152-149-AC2-B0-26-620-131-C | Carling Technologies |
Magnetic Circuit Breaker,
Datasheet
Compare
| Min.:1 Mult.:1 | - | Panel Mount | - | Carling Technologies | 1 | - | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Bulk | - | - | Active | - | Details | - | 4.585615 oz | 277 V | 80 VDC | - | A | - | - | Supplementary Protector / Motor Controller | Circuit Breakers | 20A | - | - | - | CSA, UL | Rocker | - | 2 | None | Magnetic (Hydraulic Delay) | - | Circuit Breakers | - | Circuit Breakers | - | - | - | ||
| AC2-B0-26-620-131-C |
Index :
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ

